SSB Farm Tractor Parts, Manuals & Antique TractorsAftermarket Farm & Old Antique Tractor PartsTractor Service, Repair & Owners Operators Manual ShopTractor ImplementsTractor SeatsTractor Front End LoadersPedal Toy Tractors Farm Tractors For Sale ClassifiedsAntique Tractors For Sale ClassifiedsTractors Forum - Help & AdviceTractor, Gardening, Mowers & Outdoor Equipment BooksTractor ProductsContact Us
SEARCH MANUALS
FIND PARTS

Search This Message Board:
Posted by farmm on Saturday, July 25, 2009:

In Reply to: L185DT electrical issue posted by JC on Thursday, July 23, 2009:

Is it a new switch? or a cleaned one. A proper switch turns on the oil and alternator lights when turned on. Power to the glow plugs may be independent of this. Off there should be no battery drain. Sounds like the switch is still not turning off. If that model has a mechanical fuel shut to stop the tractor, then there is no solinoid that comes into play, just the ampmeter and oil sensors.
Try to find a new switch or one that can work if wired correctly. Kubota dealers should be able to get you a new switch that will work.