SSB Farm Tractor Parts, Manuals & Antique TractorsAftermarket Farm & Old Antique Tractor PartsTractor Service, Repair & Owners Operators Manual ShopTractor ImplementsTractor SeatsTractor Front End LoadersPedal Toy Tractors Farm Tractors For Sale ClassifiedsAntique Tractors For Sale ClassifiedsTractors Forum - Help & AdviceTractor, Gardening, Mowers & Outdoor Equipment BooksTractor ProductsContact Us
SEARCH MANUALS
FIND PARTS

Search This Message Board:
Posted by Tom on Saturday, July 17, 2010:

In Reply to: Deere 455 Intermittent mower deck PTO posted by Tom on Friday, January 22, 2010:

Well, it took awhile, but I finally have it figured out.

The issue is (was) a wire connection block just above the circuit board on the right hand side which includes the two indicator (red and green) lights. As it turns out, once the tractor reached a high temps, the yellow wire in the block would loose contact and the PTO -mower deck- would shut down. Once cooled down, the connection would make up again and all would be good.
After I took it all apart and made sure the slide connectors were clean and tight, Issue Solved.

Hope this helps others that might have an intermittent PTO (mower deck) problem.