SSB Farm Tractor Parts, Manuals & Antique TractorsAftermarket Farm & Old Antique Tractor PartsTractor Service, Repair & Owners Operators Manual ShopTractor ImplementsTractor SeatsTrailer PartsPedal Toy Tractors Farm Tractors For Sale ClassifiedsAntique Tractors For Sale ClassifiedsTractors Forum - Help & AdviceAntique Farm, Lawn & Garden Tractors BlogTractor ProductsContact Us

Search This Message Board:
Posted by jim on Sunday, June 21, 2009:

In Reply to: mag not working posted by Ron on Sunday, June 21, 2009:

That is the coil, one end of primary goes to points condensor and other end is grounded through that little tag the screw is in to hold coil in place. Primary has very low resistance and requires a very sensitive ohm meter to detect anything but an open circuit . Secondary winding will have in the neighborhood of 5 to 7 k ohms, check from primary to terminal on top of coil where high tension spark is emitted. Points are very fussy on a mag due to low voltage and are to be set at .013. You can check contact of points with the ohm meter but you have to unhook primary coil lead to do so. There are other methods course but they require additional procedures. Coil output can be tested but you need to be familiar with expected results to tell if it is good or bad.