SSB Farm Tractor Parts, Manuals & Antique TractorsAftermarket Farm & Old Antique Tractor PartsTractor Service, Repair & Owners Operators Manual ShopTractor ImplementsTractor SeatsTrailer PartsPedal Toy Tractors Farm Tractors For Sale ClassifiedsAntique Tractors For Sale ClassifiedsTractors Forum - Help & AdviceAntique Farm, Lawn & Garden Tractors BlogTractor ProductsContact Us

Search This Message Board:
Posted by lee on Sunday, June 15, 2008:

In Reply to: CAT416 simple Hyd Hose replace posted by noob416 on Sunday, June 15, 2008:

1. Any good hose shop can make the hose. they are standard O-ring face connectors. Some older use JIC connectors.

2- just operate with no load a few times to bleed out the air.

3. It take 10W oil. Here is what Cat states about it.

Hydraulic Oil



Applications

Hydraulic Systems

Hydrostatic Transmissions


Cat HYDO (Hydraulic Oil)
Cat HYDO (Hydraulic Oil) is formulated with a balanced additive system that includes detergents, rust inhibitors, antiwear agents and defoamers.


Cat HYDO Advanced 10 (Hydraulic Oil)
Cat HYDO Advanced 10 (SAE 10W) is designed to provide extended oil drain intervals and to provide extra protection to Cat hydraulic system components.

Cat HYDO Advanced 10 is a combination of premium additives and premium base stock that pass severe qualification testing requirements in order to provide superior protection for Cat hydraulic systems.

Cat HYDO Advanced 10 has a 50% increase in the standard oil drain interval for machine hydraulic systems (3000 hours versus 2000 hours) over second and third choice oils - when following the maintenance interval schedule for oil filter changes and for oil sampling that is stated in the Operation and Maintenance Manual for your particular machine. 6000 hour oil drain intervals are possible with Cat HYDO Advanced 10 when using S·O·S Services oil analysis. Contact your Cat dealer for details.

Cat HYDO Advanced 10 offers the following benefits: protection against mechanical wear, rusting and corrosive wear in hydraulic systems and in hydrostatic transmission systems. Cat HYDO Advanced 10 should be used to achieve maximum life and maximum performance from hydraulic system components and from hydrostatic transmissions. In order to gain the most benefit from the improved performance designed into Cat HYDO Advanced 10, when switching to Cat HYDO Advanced 10, cross contamination with the previous hydraulic oil should be kept to less than 10%. Cat HYDO Advanced 10 is preferred in most hydraulic systems and in most hydrostatic systems when ambient temperature is between -20 °C (-4 °F) and 40 °C (104 °F).


Cat HYDO Advanced 10

If a different viscosity is required due to ambient temperatures, the following Caterpillar oils can be used:


Cat DEO Multigrade

Cat DEO-ULS

Cat DEO SYN

Cat Arctic DEO SYN

Cat TDTO

Cat Arctic TDTO

Cat TDTO-TMS

Cat MTO

Note: Caterpillar oil availability will vary by region.


Commercial Oils
Note: Non-Caterpillar commercial oils that are acceptable for use in most Cat hydraulic and hydrostatic transmission systems are as a group third choice oils. Within this grouping of third choice oils there are tiered levels of performance.



--------------------------------------------------------------------------------

NOTICE
Caterpillar does not warrant the quality or performance of non-Caterpillar fluids.


--------------------------------------------------------------------------------


The minimum viscosity for commercial alternative oils used in most Caterpillar machine hydraulic systems and in most Cat hydrostatic transmission systems is 6.6 cSt at 100 °C (212 °F) "ASTM D445".

If Caterpillar oils cannot be used, oils meeting the following commercial specifications can be used in most Cat hydraulic systems and in most Cat hydrostatic transmission systems:


Engine oils that meet the Cat ECF-1-a, Cat ECF-2, or Cat ECF-3 specifications and have a minimum zinc additive of 0.09 percent (900 ppm)

Biodegradable oils that meet the Cat BF-1 specification

TO-4 specification oils that have a minimum zinc additive of 0.09 percent (900 ppm)

Note: Industrial hydraulic oils are not recommended for use as service fill in Caterpillar machine hydraulic systems